Level of performance without an external controller: PL = d
Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: 3
Safety Integrity Level: SIL 2
Cycle after dangerous failure: B10d = 2,000,000 at 2A
Max. activation distance: 10 mm, 2 mm hysteresis
Security contacts / diagnostics AMX5 / AMX5CM12:
2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary
Security contacts AMX4: 2 x NO 2A/48V redundant
Security contacts / diagnostics AMX3:
1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary
Detection encoding: mono-code inviolable
Indicator: LED indicates code recognition
Reset: automatic
Attachment: 4 tamper-proof M4 screws (optional ref: BH4)
Mounting position: 2 (double wall brackets)
Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ?or PC (AMX5CM12)
Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12)
Water resistance: IP 67/68 (PA6 / PC) or IP 69K with stainless steel - new generation
Temperature: -25°C to +60°C
Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability
Certification: TÜV Rheinland 01/205/5238/12
License Test Mark 968/EL 214.01/12
UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)