NJ4-12GK-N | Pepperl Fuchs | Cảm biến tiệm cận NJ4-12GK-N | Inductive Sensor | Pepperl Fuchs Vietnam
NJ4-12GK-N
Pepperl & Fuchs Vietnam
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 4 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 3.24 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) | |
Switching frequency | 0 ... 1500 Hz | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | ≤ 1 mA | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
MTTFd | 11774 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP66 / IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Data for application in connection with hazardous areas | ||
Equipment protection level | Gb , Da , Mb | |
Equipment protection level Gb | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | NJ4-12GK-N... | |
ATEX certificate | PTB 00 ATEX 2048 X | |
ATEX marking | II 2G Ex ia IIC T6…T1 Gb | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx PTB 11.0037X | |
IECEx marking | Ex ia IIC T6 Ga | |
Standards | IEC 60079-0:2004 , IEC 60079-11:2006 | |
Effective internal inductivity | max. 45 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µH A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 69 °C (156.2 °F) T5 : 84 °C (183.2 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 51 °C (123.8 °F) T5 : 66 °C (150.8 °F) T4 : 80 °C (176 °F) T3 : 80 °C (176 °F) T2 : 80 °C (176 °F) T1 : 80 °C (176 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 39 °C (102.2 °F) T5 : 54 °C (129.2 °F) T4 : 61 °C (141.8 °F) T3 : 61 °C (141.8 °F) T2 : 61 °C (141.8 °F) T1 : 61 °C (141.8 °F) | |
Equipment protection level Da | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | NJ4-12GK-N... | |
ATEX certificate | PTB 00 ATEX 2048 X | |
ATEX marking | II 1D Ex ia IIIC T135°C Da | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
Effective internal inductivity | max. 45 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µH A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 80 °C (176 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 61 °C (141.8 °F) | |
Equipment protection level Mb | ||
Type of protection | intrinsic safety | |
Certificates | ||
Appropriate type | NJ4-12GK-N... | |
IECEx certificate | IECEx PTB 11.0037X | |
IECEx marking | Ex ia I | |
Standards | IEC 60079-0:2004 , IEC 60079-11:2006 | |
Effective internal inductivity | max. 45 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µH A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 80 °C (176 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 61 °C (141.8 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals |
GREENTECH Việt Nam - Công ty TNHH TM DV GREENTECH là nhà XNK hàng đầu và là nhà cung cấp chuyên nghiệp các mặt hàng tự động, thiết bị điện và điện công nghiệp,.... Bên cạnh đó chúng tôi là nhà thực hiện các giải pháp tích hợp trong công nghiêp, dân dụng, xây dựng,... Chúng tôi đáp ứng mọi xu hướng công nghiệp hóa, hiện đại hóa hiện nay
Liên hệ cho chúng tôi để CÓ thông tin mà Quý khách CẦN.
[ Email ] nhan@greentechvn.com | sales@greentechvn.com | ltnhan.gh@gmail.com
Online contact========
Yahoo: nhan.luongthe
Skype: luongthenhan
===================
Greentech Trading Service Company Limited
[ Main Office ] 33 Street DC5, Son Ky Ward, Tan Phu District, HCM City, Vietnam
[ Branch Office ] 92/8 Huynh Thuc Khang Street, Tam Ky City, Quang Nam Province, Viet Nam
[ Tel & Fax ] + 84 (0) 28 3816 1314
[ Website ] http://greentechvn.com | http://greentechvn.net
[ Face Page ] https://www.facebook.com/greentechvietnam/
-------------------------------
Ø Flow, pressure and level measurement | Temperature and humidity measurement | Position measurement | Force measurement
Ø Optical and acoustic measurement | Electrical measurement | Hydraulics – Pneumatic
Ø Valve - Pipes, tubes and fittings
Ø Building Management System
aØ Smarthome
µ FAST - FLEXIBLE - FLASH µ
-------------------------------------------------------------------
Kikusui Vietnam | Wenglor Vietnam | Sprecher Schuh Vietnam | Pelco Vietnam | Solvac Vietnam | Citizen Vietnam | Pizzato Elettrica Vietnam | Renishaw Vietnam | Di-soric Vietnam | Nemicon Vietnam | Moog Vietnam | DSTI Vietnam | Boll & Kirch Vietnam | Euchner Vietnam | Samson Vietnam | Lafert Vietnam | Sunon Vietnam | Mc Donnell Miller Vietnam | NSD Vietnam| Hitrol Vietnam | LS Vietnam | TDE Macno Vietnam | Parker Vietnam | Metrix Vietnam | SMC Vietnam | Gems Sensor & Control Vietnam | Bacharach Vietnam | Asco Vietnam | Showa Denki Vietnam | Sauter Vietnam | Land Ametek Vietnam | Vaisala Vietnam | Optris Vietnam | Tetra-K Electronic Vietnam | Bionics Vietnam | Bionics Instrument Vietnam | Puls Vietnam | Hager Vietnam | Kava Vietnam | Mitsubishi Vietnam | Siemens Vietnam | Omron Viet Nam | TPM Vietnam | Tecsis Vietnam | Wise Control Vietnam | Micro Process Controls Vietnam | Wika Vietnam | Asahi Gauge Vietnam | TemPress Vietnam | Itec Vietnam | Konics Vietnam | Ashcroft Vietnam | Ametek Vietnam – Afriso Vietnam | LS Industrial Vietnam | RS Automation Vietnam | Balluff Vietnam | Baumer Vietnam | Kuppler Vietnam | Pulsotronics Vietnam | Leuze Vietnam | Microsonic Vietnam | AST Vietnam | Tempsen Vietnam | STS Vietnam | Micro Dectector Vietnam | Proxitron Vietnam | Microsens Vietnam | Towa Seiden Vietnam | Promesstec Vietnam | Ski Vietnam | Eltra Vietnam | Hohner Vietnam | Posital Vietnam | Elap Vietnam | Beisensors Vietnam | Newall Vietnam | Dotech Vietnam | Watlow Vietnam | Bihl Weidemann Vietnam | Prosoft Vietnam | ICP DAS Vietnam | Beckhoff Vietnam | Keller M S R Vietnam | IRCON Vietnam | Raytek Vietnam | Kimo Vietnam | YSI Vietnam | Jenco Vietnam | Tekhne Vietnam | Atago Vietnam | E Instrument Vietnam | IMR Vietnam | Netbiter Viêt Nam | FMS Vietnam | Unipulse Vietnam | Migun Vietnam | Sewha Vietnam | HBM Vietnam | Pilz Vietnam | Dold Vietnam | EBMpapst Vietnam | Puls Vietnam | Microsens Vietnam | Controller Sensor Vietnam | Mark|10 Vietnam | Schmidt Vietnam | Bernstein Vietnam | Celduc Vietnam | Univer Vietnam | Waicom Vietnam | Aignep Vietnam | Top Air Vietnam | Burket Vietnam | Gemu Vietnam | JJ Automation Vietnam | Somas Vietnam | Delta Elektrogas Vietnam | Pentair Vietnam | Auma Vietnam | Sipos Artorik Vietnam | Flowserve Vietnam | Sinbon Vietnam | Setra Vietnam | Yottacontrok Vietnam | Sensor Tival Vietnam | Vaisala Vietnam | Crouzet Vietnam | RheinTacho Vietnam | Cityzen Seimitsu Vietnam | Flowserve Vietnam | Greatork Vietnam | PS Automation Vietnam | Bettis Vietnam | Sinbon Vietnam | Setra Vietnam | Laurel Vietnam | Datapaq Vietnam | EE Electronik Vietnam | Banico Vietnam | Sinfonia Vietnam | Digmesa Vietnam | Alia Vietnam | Flowline Vietnam | Brook Instrument Vietnam | Dakota Instrument Vietnam | Diehl Metering Vietnam | Stego Vietnam | Rotronic Vietnam | Hopeway Vietnam | Beko Vietnam | Matsui Vietnam | Westec Vietnam | Sometech Vietnam | Offshore Vietnam | DCbox Vietnam | Fanuc Vietnam | KollMorgen Vietnam | Endress & Hauser Vietnam | Metso Automation Vietnam | MKS Instruments Vietnam | Teledyne Instruments Vieatnam | Badger Meter Vietnam | Hirschmann Vietnam | Servo Mitsubishi Vietnam | SCR SA Việt Nam | Biotech Flow Meter Việt Nam | Thermo Electric Việt Nam | Siko Việt Nam | Klinger Việt Nam | HK Instrument Việt Nam | Magnetrol Viet Nam | Lika Viet Nam | Setra Viet Nam | Kistler Viet Nam | Renishaw Viet Nam | Mindmen Vietnam | Airtac Vietnam | Gimatic Vietnam | Monarch Instrument Vietnam | Stauff Vietnam | Burster Vietnam | SDT International Vietnam | MTI Instrument Vietnam | Zhuzhou CRRC Vietnam | Sensorex Vietnam | TWK Elektronik Vietnam | ASC Vietnam | Ronds Vietnam | Klaschka Vietnam | Hubner Vietnam | Hainzl Vietnam | Labom Vietnam | Siko Vietnam | Rittmeyer Vietnam | TR Electronic Vietnam | AK Industry Vietnam | Precizika Metrology Vietnam | Dis Sensor Vietnam | Elap Vietnam | Wachendorff Automation Vietnam | Foxboro Vietnam | Fireray Vietnam | Fiessler Elektronik Vietnam | Watt Drive Vietnam | Murr Elektronik Vietnam | Zander Vietnam | Elgo Vietnam | Measurex Vietnam | Saia Burgess Control Vietnam | Cabur Vietnam | Castel Vietnam | Elettromeccanica CDC Vietnam | Piab Vietnam | Coval Vietnam | Fipa Vietnam | Zimmer Vietnam | Vmeca Vietnam | Anver Vietnam | Pentair Vietnam | Aignep Vietnam | Festo Vietnam | Keyence Vietnam | Gessmann Vietnam | Balluff Vietnam | Wohner Vietnam | Wieland Vietnam | Weidmuller Vietnam | Tempatron Vietnam | Telco Sensor Vietnam | TeknoMega Vietnam | Synatel Vietnam | Turck Vietnam | Condor VietNam | SmartScan VietNam | Knick Vietnam | Sera Vietnam | Sera Seybert + Raheir Vietnam | Finder Vietnam | Speck Pumpen Vietnam | Promesstec Vietnam | Infranor Vietnam | Parker SSD Parvex | Pees Component Vietnam | Danfoss VietNam | Ropex Vietnam | Lenord + Bauer Vietnam | Herion Vietnam | Helukabel Vietnam | Burkert Vietnam | Chetronics Vietnam | Megger Vietnam | Systron Donner Vietnam| Waycon Vietnam | Spohn & Burkhardt Vietnam | TRElectronic Vietnam | TWK Elektronik Vietnam | Electro Sensor Vietnam | TRumeter Vietnam | Atek Vietnam | Magnescale Vietnam | Lenord Bauer Vietnam | IPF Electronic Vietnam | Italsensor Vietnam | Nidec Vietnam | Scancon Vietnam | Celesco Vietnam | Carroll & Meynell Vietnam |
-----------------------------------------------
Bình luận