Sick UE410-4RO3 | Rơ le kỹ thuật số Sick UE410-4RO3 | Digital Relay Sick UE410-4RO3 | Sick Việt Nam

Online Support

Technical - Mr. Nhân: 0935 04 1313 -  nhan@greentechvn.com

Technical - Mr. Nhân: 0935 04 1313 - nhan@greentechvn.com

Sales - Mr. Nhân: 0935 04 1313 -  sales@greentechvn.com

Sales - Mr. Nhân: 0935 04 1313 - sales@greentechvn.com

HCM Sale - Ms. Thủy: 079 664 0303 - thuy@greentechvn.com

HCM Sale - Ms. Thủy: 079 664 0303 - thuy@greentechvn.com

HCM Sale - Mr. Sơn:  0903 392 551  -  son@greentechvn.com

HCM Sale - Mr. Sơn: 0903 392 551 - son@greentechvn.com

HCM Sale 01: 0903 355 093 - sale01@greentechvn.com

HCM Sale 01: 0903 355 093 - sale01@greentechvn.com

HCM Sale 04: 0903 355 609 - sale04@greentechvn.com

HCM Sale 04: 0903 355 609 - sale04@greentechvn.com

HCM Sale 05: 0903 355 926 - sale05@greentechvn.com

HCM Sale 05: 0903 355 926 - sale05@greentechvn.com

CN Hà Nội - Mr. Thái: 0987040968 - thai@greentechvn.com

CN Hà Nội - Mr. Thái: 0987040968 - thai@greentechvn.com

Danh mục sản phẩm

News

Best Sale

Fanpage Facebook

Thống kê

  • Đang online 0
  • Hôm nay 0
  • Hôm qua 0
  • Trong tuần 0
  • Trong tháng 0
  • Tổng cộng 0
Sick UE410-4RO3 | Rơ le kỹ thuật số Sick UE410-4RO3 | Digital Relay Sick UE410-4RO3 | Sick Việt Nam

Sick UE410-4RO3 | Rơ le kỹ thuật số Sick UE410-4RO3 | Digital Relay Sick UE410-4RO3 | Sick Việt Nam

(1 đánh giá)

Sick UE410-4RO3 | Rơ le kỹ thuật số Sick UE410-4RO

Sick Việt Nam

Sick UE410-4RO3 | Rơ le kỹ thuật số Sick UE410-4RO3 | Digital Relay Sick UE410-4RO3 | Sick Việt Nam

  • Category Category 4 (EN ISO 13849)
    Performance level PL e (EN ISO 13849)
  • Interfaces

    Outputs 4 enabling current paths
    Number of control inputs 2 (B1, B2)
    Number of enable current contacts 4 (13/14, 23/24, 33/34, 43/44)
    Number of signaling current paths 2 (Y14, Y24)
    Number of signaling current contacts 2 (Y1/Y2, Y3/Y4)
    Connection type Plug-in screw-type terminals
    Display elements LEDs
  • Electrical data

    Protection class III (EN 61140)
    Voltage supply Via FLEXBUS+
    Power consumption ≤ 3.2 W
    Internal power consumption ≤ 3.2 W 1)
    Overvoltage category II (EN 61131-2)
    Switching inputs  
    Terminals B1, B2
    Input voltage 18 V DC ... 30 V DC
    Enabling current paths  
    Terminals 13/14, 23/24, 33/34, 43/44
    Type of output Potential-free NO contacts, positively guided
    Switching voltage 5 V AC/DC ... 253 V AC/DC
    Current-carrying capacity per OSSD 10 mA ... 6 A
    Signaling current paths  
    Terminals Y14, Y24
    Type of output NO contact, connected to internal 24 V DC, positively guided, current-limited
    Output voltage 16 V DC ... 30 V DC
    Output current ≤ 75 mA
    Check-back current paths  
    Terminals Y1/Y2, Y3/Y4
    Type of output Potential-free NC contacts, positively guided
    Switching voltage 5 V AC/DC ... 253 V AC/DC
    Current-carrying capacity per OSSD 10 mA ... 6 A
  • Category Category 4 (EN ISO 13849)
    Performance level PL e (EN ISO 13849)
  • Interfaces

    Outputs 4 enabling current paths
    Number of control inputs 2 (B1, B2)
    Number of enable current contacts 4 (13/14, 23/24, 33/34, 43/44)
    Number of signaling current paths 2 (Y14, Y24)
    Number of signaling current contacts 2 (Y1/Y2, Y3/Y4)
    Connection type Plug-in screw-type terminals
    Display elements LEDs
  • Electrical data

    Protection class III (EN 61140)
    Voltage supply Via FLEXBUS+
    Power consumption ≤ 3.2 W
    Internal power consumption ≤ 3.2 W 1)
    Overvoltage category II (EN 61131-2)
    Switching inputs  
    Terminals B1, B2
    Input voltage 18 V DC ... 30 V DC
    Enabling current paths  
    Terminals 13/14, 23/24, 33/34, 43/44
    Type of output Potential-free NO contacts, positively guided
    Switching voltage 5 V AC/DC ... 253 V AC/DC
    Current-carrying capacity per OSSD 10 mA ... 6 A
    Signaling current paths  
    Terminals Y14, Y24
    Type of output NO contact, connected to internal 24 V DC, positively guided, current-limited
    Output voltage 16 V DC ... 30 V DC
    Output current ≤ 75 mA
    Check-back current paths  
    Terminals Y1/Y2, Y3/Y4
    Type of output Potential-free NC contacts, positively guided
    Switching voltage 5 V AC/DC ... 253 V AC/DC
    Current-carrying capacity per OSSD 10 mA ... 6 A