2S-2S2W | 2L-2S2W | 2 Pump Control Water Level Controller | Bộ điều khiển 2 mức cho bơm

Hổ trợ trực tuyến

Technical - Mr. Nhân: 0935 04 1313 -  nhan@greentechvn.com

Technical - Mr. Nhân: 0935 04 1313 - nhan@greentechvn.com

Sales - Mr. Nhân: 0935 04 1313 -  sales@greentechvn.com

Sales - Mr. Nhân: 0935 04 1313 - sales@greentechvn.com

HCM Sale - Ms. Thủy: 079 664 0303 - thuy@greentechvn.com

HCM Sale - Ms. Thủy: 079 664 0303 - thuy@greentechvn.com

HCM Sale - Mr. Sơn:  0903 392 551  -  son@greentechvn.com

HCM Sale - Mr. Sơn: 0903 392 551 - son@greentechvn.com

HCM Sale 01: 0903 355 093 - sale01@greentechvn.com

HCM Sale 01: 0903 355 093 - sale01@greentechvn.com

HCM Sale 04: 0903 355 609 - sale04@greentechvn.com

HCM Sale 04: 0903 355 609 - sale04@greentechvn.com

HCM Sale 05: 0903 355 926 - sale05@greentechvn.com

HCM Sale 05: 0903 355 926 - sale05@greentechvn.com

CN Hà Nội - Mr. Thái: 0987040968 - thai@greentechvn.com

CN Hà Nội - Mr. Thái: 0987040968 - thai@greentechvn.com

Danh mục sản phẩm

Tin tức cần biết

Sản phầm bán chạy

Fanpage Facebook

Thống kê

  • Đang online 0
  • Hôm nay 0
  • Hôm qua 0
  • Trong tuần 0
  • Trong tháng 0
  • Tổng cộng 0
2S-2S2W | 2L-2S2W | 2 Pump Control Water Level Controller | Bộ điều khiển 2 mức cho bơm

2S-2S2W | 2L-2S2W | 2 Pump Control Water Level Controller | Bộ điều khiển 2 mức cho bơm

(1 đánh giá)

2S-2S2W

Twoline Level Vietnam | Greentech Vietnam

12 tháng

2S-2S2W | 2L-2S2W | 2 Pump Control Water Level Controller | Bộ điều khiển 2 mức cho bơm

.

Quick Level Controller

Model2S-2S2W / 2L-2S2W
designation2 Pump Control Water Level Controller
Input VoltageAC 220V (100V option)
Contact capacity1 AC 3 ~ 5A 22OV PUMP- HI / AL 220V AC 3A
Characteristic2 Line Method (Unit and Sensor)
function2 high water level alarm and pump control (type electrode Ottogi way combination)
Sensor materialHEAD - P / P, FLOAT- P / P foam rope - P / P, Chu - STEEL / SUS
 
Model2S-2S2WC / 2L-2S2WC
designation2 Pump Control Water Level Controller
Input VoltageAC 220V (100V option)
Contact capacity22OV 5A AC CONTROL HI / AL 220V AC 3A
Characteristic2 Line Method (Unit and Sensor)
functionTwo alternating pump control and control and high level alarm (electrode type Ottogi way combination)
Sensor materialHEAD - P / P, FLOAT- P / P foam rope - P / P, Chu - STEEL / SUS
 Characteristic
  • 2S-2S2W/2S2WC, 2L-2S2W/2S2WC is Ottogi way as the water level sensor and regulator unit between the two lines connected to the supply / drainage pumps and automatic control and two alternating high water level alarm and control the water level, which can save labor costs as regulators no need to distinguish it from -, wire-saving, saving pipes, lines separated on several factors completely resolved, as the water level controls of the new lines and even type 2 +, in accordance with the
  •  
  • 2S-2S2W type is rich in socket type contacts. (A˝ contact)
  • 2S-2S2W-D and DC type is the LO-ALARM contact
 Usage
  • Used for sewage
  • Use of septic tanks, etc., where corrosive resistant
  • Use a water tank or other debris, a lot of places
  • When you want to use alternate control for only the control unit will alternate alternate (see sticker)
  • Using seawater (salt water), etc.
 Wiring Diagram

 At installation

  • Teuneun socket 2 "(50mm) attached to the socket where you want to install, and then be welded using a wrench must use a wrench After more than 65φ. (However, after City wrench type to be ordered separately)
  • Installing place shall be selected by installation where there is no jam in the hood or around the radius of 30cm × 30cm does not light up when there is the will of the inhalation (hood) burae inhaled attention needed
  • A string of rope should not necessarily tie loosened
  •  
  • The factory will produce 2 "socket type

When wiring

  • HH, PH, PL, as shown in the white line black is black connector should inherit a twist as white.(When connector is snapped to black. Bags NO CLASSIFICATION required)
  • LL is also true there are attempts
  • Reed S / W, please see the burae during width adjustment, so a little more work on a horizontal climb
  • 2 high water level alarm and pump control (2L-2S2W)
  • Two alternating pump control and control and high level alarm (2L-2S2WC)

 

rescue

  • A built-in within the lead FOLAT S / W is a special molding process is semi-permanent because the operation by the voltage change of the lead S / W and a resistance-voltage, low-current, because in use failed to separate other contact applications
  • Be sure to use the separating burae
 Order reference
  • Please see the Ottogi Please use a ball (HH) when used for other purposes contacts (red ball) to be ordered separately for other purposes when used separately. (Using more than 60 ℃)
  • HI / LO ALARM using the Use of 2S2W-D / DC type. (D-type is a two-stage, two-stage DC-type are alternately controlled)
  • 100V Please pause is ordered separately. (Which is fixed at the factory 220V)
 External unit

 caution

  • There are four types burae
  • HH- high level contacts AC / DC 48V or less used 1A (NO A contact)
  • Drainage starts -2 (2㏀)
  • Drainage starts -1 (3.3㏀)
  • Drain pump stops (Pump 1, 2) 5.6㏀
  • PH, PL, LL ball should not be used as a general purpose contact. (The internal resistance)
  • Various water tanks, water tanks, septic tanks, water level adjustment of the drainage, sewage, etc.
  • 2-wire +, - NO CLASSIFICATION
  •  
  • Note: The steam generation, high-temperature tank (over 60 ℃) Not available
designationElectrode type level regulators
Model
  • 2S-4P2W
  • 2L-4P2W
Input VoltageAC 220V (100V option)
Contact capacity22OV 5A AC CONTROL HI / LO 220V AC 3A
Characteristic2 Line Method (Unit and Sensor) socket type (rich contact output)
functionFor grade / high water level alarm and automatic drainage device
  • For high water level control and alarm devices of various water tanks, drainage tanks
  • 2-wire +, - NO CLASSIFICATION
  •  
  • Caution: oil, chemicals, steam generating tank (over 60 ℃) Not available
designationElectrode type level regulators
Model
  • 2S-5P2W
  • 2L-5P2W
Input VoltageAC 220V (100V option)
Contact capacity22OV 5A AC CONTROL HI / LO 220V AC 3A
Characteristic2 Line Method (Unit and Sensor) socket type (rich contact output)
functionFor supply / drainage automatic mitgo / low level alarms
  • For high water level control and alarm devices of various water tanks, drainage tanks
  • 2-wire +, - NO CLASSIFICATION
  •  
  • Note: chemicals, steam generating tank (over 60 ℃) Not available
designationOttogi expression level regulator
Model
  • 2S-3Q2W
  • 2L-3Q2W
Input VoltageAC 220V (100V option)
Contact capacity22OV 5A AC HI / LO 220V AC 3A
Characteristic2 Line Method (Unit and Sensor) socket type (rich contact output)
functionFor grade / high water level alarm and automatic drainage device
  • Level control and high level alarm system / septic tanks, sewage, drainage, only for
  • 2-wire +, - NO CLASSIFICATION
  •  
  • Note: The steam generation, high-temperature tank (over 60 ℃) Not available
designationOttogi expression level regulator
Model
  • 2S-4Q2W
  • 2L-4Q2W
Input VoltageAC 220V (100V option)
Contact capacity22OV 5A AC CONTROL HI / LO 220V AC 3A
Characteristic2 Line Method (Unit and Sensor) socket type (rich contact output)
functionFor supply / drainage automatic mitgo / low level alarms
  • Various water tanks, water tanks, septic tanks, drainage, and water level control for high / low level alarm devices, such as sewage
  • Septic tanks, sewage, drainage, private
  • 2-wire +, - NO CLASSIFICATION
  •  
  • Note: The steam generation, high-temperature tank (over 60 ℃) Not available
designation2 Pump Control Water Level Controller
Model
  • 2S-2S2W
  • 2L-2S2W
Input VoltageAC 220V (100V option)
Contact capacity2 ~ 5A AC 22OV PUMP1 HI / ALARM 220V AC 3A
Characteristic2 Line Method (Unit and Sensor) socket type (rich contact output)
function2 high water level alarm and pump control (type electrode Ottogi way combination)
  • 2 for high water level alarm and pump control various devices, such as water tanks, water tanks, septic tanks, drainage, sewage
  • Septic tanks, sewage, drainage, private
  • 2-wire +, - NO CLASSIFICATION
  •  
  • Note: The steam generation, high-temperature tank (over 60 ℃) Not available
designation2 Pump Control Water Level Controller
Model
  • 2S-2S2WC
  • 2L-2S2WC
Input VoltageAC 220V (100V option)
Contact capacity2 ~ 5A AC 22OV PUMP1 HI / ALARM 220V AC 3A
Characteristic2 Line Method (Unit and Sensor) socket type (rich contact output)
functionTwo alternating pump control and control and high level alarm (electrode type Ottogi way combination)
  • 2 for high water level alarm and pump control various devices, such as water tanks, water tanks, septic tanks, drainage, sewage
  • Septic tanks, sewage, drainage, private
  • 2-wire +, - NO CLASSIFICATION
  •  
  • Note: The steam generation, high-temperature tank (over 60 ℃) Not available
designation3 Pump Control Water Level Controller
Model
  • 2S-3S2W / 3S2WC
  • 2L-3S2W / 3S2WC
Input VoltageAC 220V (100V option)
Contact capacity3 ~ 5A AC 22OV PUMP1 HI / ALARM 220V AC 3A
Characteristic2 Line Method (Unit and Sensor) socket type (rich contact output)
function3 alternating pump control and control and high level alarm
  • Various water tanks, water tanks, septic tanks, drainage, for the three alternating pump control and alarm system control and high level of sewage, etc.
  • Septic tanks, sewage, drainage, private
  • 2-wire +, - NO CLASSIFICATION
  •  
  • Note: The steam generation, high-temperature tank (over 60 ℃) Not available
designationFLOAT type liquid level regulators
Model
  • 2S-5F2W
  • 2L-5F2W
Input VoltageAC 220V (100V option)
Contact capacity5A 220V AC CONTROL HI / LO 220V AC 3A
Characteristic2 Line Method (Unit and Sensor) socket type (rich contact output)
functionFor supply / drainage and automatic high / low level alarm device
  • Various water tanks, pay tanks, septic tanks, liquid level control and high / low level alarm device, the expansion tank, pressure tank, condenser tank
  • 2-wire +, - NO CLASSIFICATION
  • Order high temperature and special purpose production
  •  
  • Note: chemicals, tank temperature (above 80 ℃) Not available
designationLevel Indicating Controller
Model
  • 2S-LIC-D
  • 2L-LIC-D
Input VoltageAC 220V (100V option)
Contact capacity5A 220V AC CONTROL HI / LO 220V AC 3A
CharacteristicResistance method instead of the sensor head and the amplifier mode (0 ~ 300Ω) socket type (rich contact output)
functionFor instructions and supply / drainage and automatic high / low level alarm devices of various tanks
  • For instructions and supply / drainage and automatic high / low level alarm devices such as various kinds of water tank, oil tank (built-in panel)
  • 2 seonbyeongryeol system (sensors and directed meter) 0 ~ 300Ω (0 ~ 1.5V)
  • Order high temperature and special purpose production
  •  
  • Note: chemicals, tank temperature (above 80 ℃) Not available
designationLevel Indicating Controller
Model2L-LIC-D / P
Input VoltageAC 220V (100V option)
Contact capacity5A 220V AC CONTROL HI / LO 220V AC 3A
inputHow resistance than the way the sensor head amplifier (0 ~ 300Ω)
functionFor instructions and supply / drainage and automatic high / low level alarm devices of various tanks
CUT Panel92 × 45/98 × 50 × 102
  • For instructions and supply / drainage and automatic high / low level alarm devices such as various kinds of water tank, oil tank (external panel)
  • 2-wire serial mode (sensor and meter instructions)
  • Order high temperature and special purpose production
  •  
  • Note: chemicals, tank temperature (above 80 ℃) Not available
designationLevel Indicating Controller
Model
  • 2S-LIC-D
  • 2L-LIC-D
Input VoltageAC 220V (100V option)
Contact capacity5A 220V AC CONTROL HI / LO 220V AC 3A
inputCurrent input (4 ~ 20mA) Socket type (rich contact output)
functionFor instructions and supply / drainage and automatic high / low level alarm devices of various tanks
  • For instructions and supply / drainage and automatic high / low level alarm devices such as various kinds of water tank, oil tank (built-in panel)
  • 2-wire serial mode (sensor and meter instructions) 4 ~ 20mA
  • Order high temperature and special purpose production
  •  
  • Note: chemicals, tank temperature (above 80 ℃) Not available
designationLevel Indicating Controller
Model2L-LIC-D / P
Input VoltageAC 220V (100V option)
Contact capacity5A 220V AC CONTROL HI / LO 220V AC 3A
inputCurrent input (4 ~ 20mA)
functionFor instructions and supply / drainage and automatic high / low level alarm devices of various tanks
CUT Panel92 × 45/98 × 50 × 102
  • Mass tank, and instructions for supply / drainage and automatic high / low level alarm device such as a fuel tank (external panel)
  • 2-wire serial mode (sensor and meter instructions) 4 ~ 20mA
  • Order high temperature and special purpose production
  •  
  • Note: chemicals, tank temperature (above 80 ℃) Not available
designationLevel indicator
Model2L-LI
Input VoltageAC 220V (100V option)
Input / Output0 ~ 300Ω / 4 ~ 20mA (option) meter output voltage 0 ~ 1.5V (%)
CharacteristicIndicator of the way that a separate unit (built-in amplifier panel meter)
functionLiquid level indication of the various tanks
panel100 Φ
size110 × 110 × 92
  • Liquid level indication of the various water tank, oil tank
  • Two parallel lines (sensor and ambient meter) 0 ~ 300Ω (0 ~ 1.5V)
  • Order high temperature and special purpose production
  •  
  • Note: chemicals, tank temperature (above 80 ℃) Not available
designationLevel indicator
Model2L-LI-D / P
Input VoltageAC 220V (100V option)
Input / Output0 ~ 300Ω / 4 / 20mA (option) meter output voltage 0 ~ 1.5V (%)
CharacteristicIndicator of the way that a separate unit (built-in amplifier panel meter)
functionLiquid level indication of the various tanks
CUT Panel92 × 45
size98 × 50 × 102
  • Liquid level indication of the various water tank, oil tank
  • Two parallel lines (sensor and ambient meter)
  • 0 ~ 300Ω (0 ~ 1.5V)
  • Order high temperature and special purpose production
  • Note: chemicals, tank temperature (above 80 ℃) Not available
designationLevel indicator
Model2L-LI-D / P
Input VoltageAC 220V (100V option)
indication0-100%
inputInput current (4 / 20mA)
functionLiquid level indication of the various tanks
CUT Panel92 × 45
size98 × 50 × 102
  • Liquid level indication of the various water tank, oil tank
  • 2-wire serial mode (sensor and ambient meter) 4 ~ 20mA
  • Order high temperature and special purpose production
  •  
  • Note: chemicals, tank temperature (above 80 ℃) Not available
designationSignal Converter
Model2L-SC
Input VoltageAC 220V (100V option)
Print4 / 20mA meter output voltage. 0 ~ 1.5V (%)
inputInput resistance (0 ~ 300Ω)
functionInstructions for various tank liquid level
size49 × 61 × 98
  • Liquid level indication of the various water tank, oil tank. Two parallel lines (sensor and ambient meter)
  • 0 ~ 300Ω (0 ~ 1.5V)
  • Order high temperature and special purpose production
  •  
  • Note: chemicals, tank temperature (above 80 ℃) Not available
designationDigital Meter
Model2L-DM-V
Input VoltageAC 220V (100V option)
input0 ~ 1.5V
indication0-100%
functionFor level indication
CUT Panel92 × 45
size98 × 50 × 102
 
designationDigital Meter
Model2L-DM-A
Input VoltageAC 220V (100V option)
input4 ~ 20mA
indication0-100%
functionFor level indication
CUT Panel92 × 45
size98 × 50 × 102
designationPower supply
Model2L-DC
Input VoltageAC 220V (100V option)
CharacteristicPower supply units for current input
PrintDC 24V 500mA
function(4 / 20mA) Power supply for instructions
size49 × 61 × 98
 
designationR / I converter
Model2L-SH
Input VoltageDC 24V / 4 ~ 20mA
Input resistance2KΩ than 700Ω ~
CharacteristicFor current type sensor head amplifier
function4 ~ 20mA for
size64Φ × 25
designationAlarm Kit
Model2L-AK
inputBuilt-in 9V battery
CharacteristicNo power supply
functionThe alarm buzzer
size82 × 160 × 63
 
designationWide-type meter
Model2L-100M
input1.5V ~ 0/4 ~ 20mA
indication0-100%
CUT Panel100Φ
size110 × 110 × 92
designationWide-type meter
Model2L-65M
input4 ~ 20mA
indication0-100%
CUT Panel65Φ
size80 × 80 × 85
 
designationVertical meter
Model2L-VTM
input4 ~ 20mA / 0 ~ 1.5V
indication0-100%
CUT Panel49 × 146
size153 × 51 × 185 (H × W × D)
designationVertical meter
Model2L-VM
input4 ~ 20mA / 0 ~ 1.5V
indication0-100%
CUT Panel38 × 96
size110 × 38 × 100 (H × W × D)
 
designationGear sensor
Model2L-GS
input1.5V ~ 0/4 ~ 20mA
CharacteristicWater tank, oil tank, ceiling height do not place
Use numbers14 to 21 times Use
functionInstructions and instructions for adjustment
designationGear sensor
Model2L-GSM
input1.5V ~ 0 4 ~ 20mA
CharacteristicWater tank, oil tank, ceiling height do not place
Use numbers14 to 21 times Use
functionInstructions and instructions for adjustment
 
designationElectrode sensor
Model2L-3P2WS
Jeongeuksu3 pole
Characteristic2-wire +, - None
functionSupply / drainage only
designationElectrode sensor
Model2L-4P2WS
Jeongeuksu4-pole
Characteristic2-wire +, - None
functionSupply / drainage automatic, high water level alarm
 
designationElectrode sensor
Model2L-5P2WS
Jeongeuksu5-pole
Characteristic2-wire +, - None
functionSupply / drainage automatic, high / low level alarm
designationOttogi sensor
Model2L-QB
Contact capacityLess than DC 48V 1A
CharacteristicA lead S / W method of the magnet and the bearing
functionOh, and waste water tank level adjustment for each S / W
size48Φ × 103 × 4M
 
designationWater Sensors
Model2L-WS
Contact capacityLess than 1A (A contact) DC48V under DC48V 1A (B-contact)
CharacteristicReed S / W method based on FLOAT
functionAnd feelings for each water tank level adjustment S / W
size29Φ × 128 × 5M
designationLeak detection sensors
Model2L-LS
Voltage sensorDC 12V (formulary)
CharacteristicFor electronic leak detection
functionFor leak alarm
 
designationAlarm board
Model2L-ALK
Input VoltageAC / DC 24V
Contact capacityAC 220V 3A
functionInput and output status alarm input and output of 10 POINT / 20 POINT

 

 -  là nhà XNK hàng đầu và là nhà cung cấp chuyên nghiệp các mặt hàng tự động, thiết bị điện và điện công nghiệp,.... Bên cạnh đó chúng tôi là nhà thực hiện các giải pháp tích hợp trong công nghiêp, dân dụng, xây dựng,... Chúng tôi đáp ứng mọi xu hướng công nghiệp hóa, hiện đại hóa hiện nay

 

Liên hệ cho chúng tôi để  thông tin mà Quý khách CẦN.

< SALE & TECHNICAL SUPPORT >

< PROJECT SUPPORT >
Email : 

-------------------------------------------------------------------

 Pelco Vietnam | Solvac Vietnam | Citizen Vietnam |  | Renishaw Vietnam | Di-soric Vietnam | |  |  | Bacharach Vietnam |  | Showa Denki Vietnam | S  |  |  | Tetra-K Electronic Vietnam |  |  |  |  |  | Mitsubishi Vietnam | Siemens Vietnam | Omron Viet Nam | TPM Vietnam | Tecsis Vietnam | Wise Control Vietnam | Micro Process Controls Vietnam | Wika Vietnam | Asahi Gauge Vietnam | TemPress Vietnam | Itec Vietnam | Konics Vietnam | Ashcroft Vietnam | Ametek Vietnam – Afriso Vietnam | LS Industrial Vietnam | RS Automation Vietnam | Balluff Vietnam | Baumer Vietnam | Kuppler Vietnam | Pulsotronics Vietnam | Leuze Vietnam | Microsonic Vietnam | AST Vietnam | Tempsen Vietnam | STS Vietnam | Micro Dectector Vietnam | Proxitron Vietnam | Microsens Vietnam | Towa Seiden Vietnam | Promesstec Vietnam | Ski Vietnam | Eltra Vietnam | Hohner Vietnam | Posital Vietnam | Elap Vietnam | Beisensors Vietnam | Newall Vietnam | Dotech Vietnam | Watlow Vietnam | Bihl Weidemann Vietnam | Prosoft Vietnam | ICP DAS Vietnam | Beckhoff Vietnam | Keller M S R Vietnam | IRCON Vietnam | Raytek Vietnam | Kimo Vietnam | YSI Vietnam | Jenco Vietnam | Tekhne Vietnam | Atago Vietnam | E Instrument Vietnam | IMR Vietnam | Netbiter Viêt Nam | FMS Vietnam | Unipulse Vietnam | Migun Vietnam | Sewha Vietnam | HBM Vietnam | Pilz Vietnam | Dold Vietnam |  | Puls Vietnam | Microsens Vietnam | Controller Sensor Vietnam | Mark|10 Vietnam | Schmidt Vietnam | Bernstein Vietnam | Celduc Vietnam | Univer Vietnam | Waicom Vietnam | Aignep Vietnam | Top Air Vietnam | Burket Vietnam |  | JJ Automation  Vietnam | Somas Vietnam | Delta Elektrogas Vietnam | Pentair Vietnam | Auma Vietnam | Sipos Artorik Vietnam | Flowserve Vietnam | Sinbon Vietnam | Setra Vietnam | Yottacontrok Vietnam | Sensor Tival Vietnam | Vaisala Vietnam | Crouzet Vietnam | RheinTacho Vietnam | Cityzen Seimitsu Vietnam | Flowserve Vietnam | Greatork Vietnam | PS Automation Vietnam | Bettis Vietnam | Sinbon Vietnam  | Setra Vietnam | Laurel Vietnam | Datapaq Vietnam | EE Electronik Vietnam | Banico Vietnam | Sinfonia Vietnam | Digmesa Vietnam | Alia Vietnam | Flowline Vietnam | Brook Instrument Vietnam | Dakota Instrument Vietnam | Diehl Metering Vietnam | Stego Vietnam | Rotronic Vietnam | Hopeway Vietnam | Beko Vietnam | Matsui Vietnam | Westec Vietnam | Sometech Vietnam | Offshore Vietnam | DCbox Vietnam | Fanuc Vietnam | KollMorgen Vietnam | Endress & Hauser Vietnam | Metso Automation Vietnam | MKS Instruments Vietnam | Teledyne Instruments Vieatnam | Badger Meter Vietnam | Hirschmann Vietnam | Servo Mitsubishi Vietnam |  SCR SA Việt Nam | Biotech Flow Meter Việt Nam | Thermo Electric Việt Nam | Siko Việt Nam | Klinger Việt Nam | HK Instrument Việt Nam | Magnetrol Viet Nam | Lika Viet Nam | Setra Viet Nam | Kistler Viet Nam | Renishaw Viet Nam | Mindmen Vietnam |  | Gimatic Vietnam | Monarch Instrument  Vietnam | Stauff  Vietnam | Burster Vietnam | SDT International Vietnam | MTI Instrument Vietnam | Zhuzhou CRRC Vietnam | Sensorex Vietnam | TWK Elektronik Vietnam | ASC Vietnam | Ronds Vietnam | Klaschka Vietnam | Hubner Vietnam | Hainzl Vietnam | Labom Vietnam | Siko Vietnam | Rittmeyer Vietnam | TR Electronic Vietnam | AK Industry Vietn

-------------------------------------------------------------------

 

 

Đánh giá sản phẩm

Bình chọn sản phẩm:

Bình luận

Sản phẩm cùng loại

Top

   (0)