Ordering details
 
Product type description AES 1235
Article number 101170049
EAN code 4030661297118
eCl@ss 27-37-19-01
 
Approval
 
Approval  BG
 USA/CAN
 
Classification
 
Standards EN ISO 13849-1, IEC 61508
PL up d
Control category up 3
PFH value 1.0 x 10-7/h
- notice up to max. 50.000 switching cycles/year and at max. 80% contact load
SIL 2
Mission time 20 Years
 
Global Properties
 
Product name AES 123x
Standards IEC/EN 60204-1, IEC 60947-5-3, EN 954-1, BG-GS-ET-14, BG-GS-ET-20
Compliance with the Directives (Y/N)  Yes
Climatic stress EN 60068-2-3, BG-GS-ET-14
Mounting snaps onto standard DIN rail to EN 60715
Terminal designations IEC/EN 60947-1
Materials
- Material of the housings Plastic, glass-fibre reinforced thermoplastic, ventilated
- Material of the contacts Ag-Ni, 0,2 µm gold flashed
Weight 160 g
Start conditions Automatic or Start button
Start input (Y/N) No
Feedback circuit (Y/N) Yes
Start-up test (Y/N) No
Reset after disconnection of supply voltage (Y/N) Yes
Automatic reset function (Y/N) Yes
Reset with edge detection (Y/N) No
Pull-in delay
- ON delay with automatic start adjustable 0,1 / 1.0 s
Drop-out delay
- Drop-out delay in case of emergency stop < 50 ms
 
Mechanical data
 
Connection type Screw connection
Cable section
- Min. Cable section 0,25 mm²
- Max. Cable section 2.5 mm²
Pre-wired cable rigid or flexible
Tightening torque for the terminals 0,6 Nm
Detachable terminals (Y/N) No
Mechanical life 20.000.000 operations
Electrical lifetime 150.000 operations for 230 VAC, 5 A (cos φ = 1)
restistance to shock 30 g / 11 ms
Resistance to vibration To EN 60068-2-6 10...55 Hz, Amplitude 0,35 mm, ± 15 %
 
Ambient conditions
 
Ambient temperature
- Min. environmental temperature 0°C
- Max. environmental temperature +55 °C
Storage and transport temperature
- Min. Storage and transport temperature −25 °C
- Max. Storage and transport temperature +70 °C
Protection class
- Protection class-Enclosure IP40
- Protection class-Terminals IP20
- Protection class-Clearance IP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp 4.8 kV
- Overvoltage category III To VDE 0110
- Degree of pollution 2 To VDE 0110
 
Electromagnetic compatibility (EMC)
 
EMC rating 10 V/m
 
Electrical data
 
Rated DC voltage for controls
- Min. rated DC voltage for controls 20.4 V
- Max. rated DC voltage for controls 27.6 V
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz -
- Max. rated AC voltage for controls, 50 Hz -
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz -
- Max. rated AC voltage for controls, 60 Hz -
Contact resistance max. 100 mΩ
Power consumption < 5 W
Type of actuation DC
Switch frequency 1 Hz
Rated insulation voltage Ui 250 V
Rated operating voltage Ue 24 VDC ±15%
Thermal test current Ithe 6 A
Operating current Ie 0,2 A
Electronic protection (Y/N) No
 
Inputs
 
Monitored inputs
- Short-circuit recognition (Y/N) optional
- Wire breakage detection (Y/N) Yes
- Earth connection detection (Y/N) Yes
Number of shutters adjustable 1 piece -> 0 piece
Number of openers adjustable 1 piece -> 2 piece
Input resistance approx. 4000 Ω at GND
Input signal "1" 10 ... 30 VDC
Input signal "0" 0 ... 2 VDC
Cable length 1000 m with 0,75 mm² (for Rated voltage)
 
Outputs
 
Stop category 0
Number of safety contacts 2 piece
Number of auxiliary contacts 0 piece
Number of signalling outputs 2 piece
Switching capacity
- Switching capacity of the safety contacts min. 10 mA, max. 6 A
- Switching capacity of the signaling/diagnostic outputs min. U−4V / Y1, Y2: max. 100 mA
Fuse rating
- Protection of the safety contacts 6 A gG D-fuse
- Fuse rating for the signaling/diagnostic outputs short-circuit proof, p-type
Signalling output Y1: Authorized operation, safety contacts on;
2 YNo authorised operation off:, safety contacts
Utilisation category To EN 60947-5-1 AC-15: 230 V / 3 A
DC-13: 24 V / 2 A
Number of undelayed semi-conductor outputs with signaling function 2 piece
Number of undelayed outputs with signaling function (with contact) 0 piece
Number of delayed semi-conductor outputs with signaling function. 0 piece
Number of delayed outputs with signalling function (with contact). 0 piece
Number of secure undelayed semi-conductor outputs with signaling function 0 piece
Number of secure, undelayed outputs with signaling function, with contact. 0 piece
Number of secure, delayed semi-conductor outputs with signaling function 0 piece
Number of secure, delayed outputs with signaling function (with contact). 0 piece
 
LED switching conditions display
 
LED switching conditions display (Y/N) Yes
Number of LED´s 1 piece
 
Integral system diagnosis ISD
 
Integral system diagnosis ISD
- The following faults are registered by the safety monitoring modules and indicated by ISD
- Failure of door contacts to open or close
- Cross-wire or short-circuit monitoring of the switch connections
- Interruption of the switch connections
- Failure of the safety relay to pull-in or drop-out
- Fault on the input circuits or the relay control circuits of the safety monitoring module
 
Miscellaneous data
 
Applications  Safety sensor
 Guard system
 
Dimensions
 
Dimensions
- Width 22.5 mm
- Height 100 mm
- Depth 121 mm
 
notice
 
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
 
notice - Wiring example
 
To secure a guard door up to PL 3 and Category #03#
Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range
The feedback circuit monitors the position of the contactors K3 and K4.
Start push button A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.
If neither start button nor feedback circuit are connected, a jumper connection must be mounted between X1 and A1.
If only one external relay or contactor is used to switch the load, the system can be classified in Control Category 3 to EN 954-1, if exclusion of the fault “Failure of the external contactor” can be substantiated and is documented, e.g. by using a reliable down-rated contactor. A second contactor leads to an increase in the level of security by redundant switching to switch the load off.
Modification for 2 NC contacts:
The safety monitoring module can be modified to monitor two NC contacts by bridging the terminals A1 and X2. The short-circuit recognition between connections then becomes inoperative.
Expansion of enable delay time:
The enable delay time can be increased from 0,1 s to 1 s by changing the position of a jumper link connection under the cover of the unit.
The wiring diagram is shown with guard doors closed and in de-energised condition.
The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.

K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal
The data and values have been checked throroughly. Technical modifications and errors excepted.
Generiert am 04.08.2016 - 04:58:49h Kasbase 3.2.4.F.64I
 
 

 Công ty TNHH TM DV GREENTECH là nhà XNK hàng đầu và là nhà cung cấp chuyên nghiệp các mặt hàng tự động, thiết bị điện và điện công nghiệp,.... Bên cạnh đó chúng tôi là nhà thực hiện các giải pháp tích hợp trong công nghiêp, dân dụng, xây dựng,... Chúng tôi đáp ứng mọi xu hướng công nghiệp hóa, hiện đại hóa hiện nay            

Liên hệ cho chúng tôi để  thông tin mà Quý khách CẦN.  

< SALE & TECHNICAL SUPPORT >
< PROJECT SUPPORT >
Email :
 sales@greentechvn.com 
-------------------------------------------------------------------

Kikusui Vietnam | |Schmersal Vietnam | Meanwell Vietnam | Riken Keiki Vietnam | Bin Master Vietnam | Eclipse Vietnam | Optech Vietnam |  | Idem Safety Switch Vietnam | Manostar Vietnam | Sew-Eurodrive Vietnam | Samson Vietnam | Lafert Vietnam | Sunon Vietnam | Mc Donnell Miller Vietnam | NSD Vietnam| Hitrol Vietnam | LS Vietnam | TDE Macno Vietnam | Parker Vietnam | Metrix Vietnam |  |  | Bacharach Vietnam |  | Showa Denki Vietnam | S  |  |  | Tetra-K Electronic Vietnam |  |  |  |  |  | Mitsubishi Vietnam | Siemens Vietnam | Omron Viet Nam | TPM Vietnam | Tecsis Vietnam | Wise Control Vietnam | Micro Process Controls Vietnam | Wika Vietnam | Asahi Gauge Vietnam | TemPress Vietnam | Itec Vietnam | Konics Vietnam | Ashcroft Vietnam | Ametek Vietnam – Afriso Vietnam | LS Industrial Vietnam | RS Automation Vietnam | Balluff Vietnam | Baumer Vietnam | Kuppler Vietnam | Pulsotronics Vietnam | Leuze Vietnam | Microsonic Vietnam | AST Vietnam | Tempsen Vietnam | STS Vietnam | Micro Dectector Vietnam | Proxitron Vietnam | Microsens Vietnam | Towa Seiden Vietnam | Promesstec Vietnam | Ski Vietnam | Eltra Vietnam | Hohner Vietnam | Posital Vietnam | Elap Vietnam | Beisensors Vietnam | Newall Vietnam | Dotech Vietnam | Watlow Vietnam | Bihl Weidemann Vietnam | Prosoft Vietnam | ICP DAS Vietnam | Beckhoff Vietnam | Keller M S R Vietnam | IRCON Vietnam | Raytek Vietnam | Kimo Vietnam | YSI Vietnam | Jenco Vietnam | Tekhne Vietnam | Atago Vietnam | E Instrument Vietnam | IMR Vietnam | Netbiter Viêt Nam | FMS Vietnam | Unipulse Vietnam | Migun Vietnam | Sewha Vietnam | HBM Vietnam | Pilz Vietnam | Dold Vietnam |  | Puls Vietnam | Microsens Vietnam | Controller Sensor Vietnam | Mark|10 Vietnam | Schmidt Vietnam | Bernstein Vietnam | Celduc Vietnam | Univer Vietnam | Waicom Vietnam | Aignep Vietnam | Top Air Vietnam | Burket Vietnam |  | JJ Automation  Vietnam | Somas Vietnam | Delta Elektrogas Vietnam | Pentair Vietnam | Auma Vietnam | Sipos Artorik Vietnam | Flowserve Vietnam | Sinbon Vietnam | Setra Vietnam | Yottacontrok Vietnam | Sensor Tival Vietnam | Vaisala Vietnam | Crouzet Vietnam | RheinTacho Vietnam | Cityzen Seimitsu Vietnam | Flowserve Vietnam | Greatork Vietnam | PS Automation Vietnam | Bettis Vietnam | Sinbon Vietnam  | Setra Vietnam | Laurel Vietnam | Datapaq Vietnam | EE Electronik Vietnam | Banico Vietnam | Sinfonia Vietnam | Digmesa Vietnam | Alia Vietnam | Flowline Vietnam | Brook Instrument Vietnam | Dakota Instrument Vietnam | Diehl Metering Vietnam | Stego Vietnam | Rotronic Vietnam | Hopeway Vietnam | Beko Vietnam | Matsui Vietnam | Westec Vietnam | Sometech Vietnam | Offshore Vietnam | DCbox Vietnam | Fanuc Vietnam | KollMorgen Vietnam | Endress & Hauser Vietnam | Metso Automation Vietnam | MKS Instruments Vietnam | Teledyne Instruments Vieatnam | Badger Meter Vietnam | Hirschmann Vietnam | Servo Mitsubishi Vietnam |  SCR SA Việt Nam | Biotech Flow Meter Việt Nam | Thermo Electric Việt Nam | Siko Việt Nam | Klinger Việt Nam | HK Instrument Việt Nam | Magnetrol Viet Nam | Lika Viet Nam | Setra Viet Nam | Kistler Viet Nam | Renishaw Viet Nam | Mindmen Vietnam | 

-------------------------------------------------------------------

Bình luận

Sản phẩm cùng loại

Hổ trợ trực tuyến

Tech. Support - nhan@greentechvn.com

Tech. Support - nhan@greentechvn.com - Mr. Nhân: 0935041313

Sales Support - sales@greentechvn.com

Sales Support - sales@greentechvn.com - Mr. Nhân: 0935041313

Sale HCM-01 - thuy@greentechvn.com

Sale HCM-01 - thuy@greentechvn.com - Ms. Thủy: 079 6640303

Sale HCM-02 - phu@greentechvn.com

Sale HCM-02 - phu@greentechvn.com - Mr. Phú: 0903 077 267

Sale HCM-03 - hanh@greentechvn.com

Sale HCM-03 - hanh@greentechvn.com - Ms. Hạnh: 0905405433

Sales Chi nhánh Quảng Nam  - han@greentechvn.com -

Sales Chi nhánh Quảng Nam - han@greentechvn.com - - Mr. Hân: 0912 635 379

Chi nhánh Hà Nội - thai@greentechvn.com

Chi nhánh Hà Nội - thai@greentechvn.com - Mr. Thái: 0987040968

Mr. Tân - Campuchia Branch +855 712 756 738

Mr. Tân - Campuchia Branch +855 712 756 738 - tan@greentechvn.com

Danh mục sản phẩm

Tin tức cần biết

Sản phầm bán chạy

Fanpage Facebook

Thống kê

  • Đang online 203
  • Hôm nay 7,639
  • Hôm qua 12,618
  • Trong tuần 39,386
  • Trong tháng 201,344
  • Tổng cộng 10,521,786

Đối tác 1

Đối tác 2

Đối tác 3

Merry Christmas
Thông tin_Technical
Happy New Year
Thông tin_Sale

Top

   (0)